Each infant space shall contain a minimum of 120 square feet (11.2 square meters) of clear floor space, excluding handwashing stations, columns, and aisles (see Glossary). There shall be an aisle adjacent to each infant space with a minimum width of 4 feet (1.2 meters) in multiple bed rooms. When single infant rooms or fixed cubicle partitions are utilized in the design, there shall be an adjacent aisle of not less than 8 feet (2.4 meters) in clear and unobstructed width to permit passage of equipment and personnel.
Multiple bed rooms shall have a minimum of 8 feet (2.4 meters) between infant beds. There shall be provision for visual privacy for each bed, and the design shall support speech privacy at a distance of 12 feet (3.6 meters). |